盐城林业局办公楼设计毕业论文
2021-12-26 13:50:58
论文总字数:57958字
摘 要
1 设计资料 3
1.1 工程概况 3
1.2 建筑结构设计的基本内容 3
1.3 设计资料 3
1.3.1气象条件 3
1.3.2抗震设防 4
1.3.3地基土的标准承载力 4
1.3.4其它条件 4
1.3. 5钢筋混凝土的条件 4
2 结构类型 4
3 框架结构设计计算 5
3.1 梁柱截面,梁跨度及柱高确定 5
3.1.1初估截面尺寸 6
(1)边横梁 6
(2)中横梁 6
(3)纵 梁 6
(4)次 梁 7
(4)柱截面尺寸的初步确定 7
3.1.2梁的计算跨度 8
3.1.3工程中柱的高度 8
3.2 荷载的均布恒载 9
3.2.1 屋面板的均布荷载 9
3.2.2屋面的均布活载 10
3.2.3楼面的均布恒载 10
3.2.4楼面均布活荷载 10
3.2.5工程中梁和柱自重 10
3.2.6 工程墙体的自重的计算如下 11
3.2.7 门窗的自重的计算 12
3.2.8 各层荷载组合 13
3.3水平地震力作用下框架的侧移验算 14
3.3.1横梁的线刚度 14
3.3.2横向框架矿柱的线刚度及侧移的刚度D值 15
3.3.3横向框架的自震周期 15
3.3.4横向地震作用计算 16
3.3.5横向框架的抗震变形验算 18
3.4 水平地震作用下,横向框架的内力分析 19
3.5 横向框架在竖向荷载作用下的内力分析 22
3.5.框架在荷载作用下的内力计算 23
3.5.3 梁在荷载作用下的内力计算 26
3.5.4 框架弯距利用二次力距分配法计算如下 26
3.5.3梁端剪力及柱轴力的计算 34
3.6 结构在风荷载作用下各框架内力分析 35
3.6.1结构风荷载的计算 35
3.6.2结构的风荷载作用下内力计算步骤 37
3.7 内力组合 42
3.7.1一般组合 42
3.7.2考虑地震的内力组合 53
3.8 截面设计 58
3.8.1结构承载力的抗力调整系数如下 58
3.8.2横向框架梁截面设计 58
3.8.3 柱截面设计 66
4 结构基础的设计 73
4.1设计参考资料 73
4.2 基础设计的计算 73
4.2.1基础荷载的计算: 73
4.2.2先初步确定基础的高度: 73
4.2.3底面尺寸的初步确定: 74
4.2.4地基承载力验算: 74
4.2.5持力层承载力验算: 75
4.2.6基础高度验算: 75
4.2.7配筋计算: 76
5 现浇板设计(标准层) 77
5.1区格板的分布 77
5.2荷载计算 78
5.3荷载跨度 78
5.4弯矩计算 78
5.4.1 A区格内力计算: 78
5.4.2 B区格内力计算: 80
5.5板的截面设计: 82
6 楼梯的设计 84
6.1 楼梯踢段板设计 84
6.1.1荷载计算 85
6.1.2梯段板截面设计 85
6.2 平台梁设计 86
6.2.1荷载计算 86
6.2.2平台梁截面设计 86
6.3 平台板计算 88
6.3.1荷载计算 88
6.3.2平台板截面设计 88
结 论 89
参考文献 90
致 谢 92
摘 要
本工程为盐城林业局办公楼设计,楼层数为5层,建筑面积5020㎡,占地面积为1064㎡,为了满足办公楼使用要求,将一层的层高定为4.5m,二层以上层高定为4.2m。本工程设计计算书计算内容全面,分别计算了楼板的配筋,框架的内力计算,内力组合,截面设计,然后计算了现浇板式楼梯,基础等等,任务书要求的设计计算。设计成果还包括了任务书要的全部建筑图和结构图。设防烈度是7度,抗震等级为三级。基础为独立基础。建筑设计方面,我结合建筑设计任务书以及建筑物的功能要求,实地考察了林业局附近工程环境。进行了建筑平面设计、立面设计和剖面设计。首先,在进行总体功能分析的基础上,确定建筑物的出入口位置以及建筑平面形状。其次分析建筑内部功能关系,结合建筑设计防火规范、中小学建筑设计规范等安排建筑各组成部分的平面位置,确定各部分房间的平面形状、面积大小和尺寸等。结构设计方面,根据板各跨的长度确定板的类型,板的厚度。荷载统计了恒载、活载、雪荷载、风荷载、地震作用等的影响,取一榀框架分别进行各荷载作用下的内力计算。其中,竖向荷载作用下采用弯矩二次分配法(也可以说分层法)计算,水平荷载作用下采用D值法进行计算。计算所得效应按照持久设计状况和地震设计状况分别进行组合,其中持久设计状况考虑恒载占控制作用和活载占控制作用,地震涉及状况采用1.2重力荷载代表值 1.3水平地震作用,从中选出最不利的情况分别进行梁、柱的配筋计算。对于独立基础的色剂,根据地基承载力确定面积,根据冲切破坏确定高度,根据基础受弯破坏确定配筋。对于其他部位的配筋,采用PKPM进行点算。
Summary
This project design calculation book calculation content comprehensive, respectively calculated the floor reinforcement, frame internal force calculation, internal force combination, section design, and then calculated the cast-in-place slab stairs, foundation, and so on, the task book requirements of the design calculation. Fortification intensity is 7 degrees, seismic grade for three. The foundation is the independent foundation. In terms of architectural design, I made a field study of the engineering environment near the forestry bureau based on the architectural design assignment and the functional requirements of the building. The architectural plane design, elevation design and section design were carried out. First, on the basis of the overall function analysis, the location of the entrance and exit of the building and the shape of the building plan are determined. Secondly, it analyzes the internal function relationship of the building, arranges the plane position of each component part of the building in combination with the building design fire code and the building design code for primary and secondary schools, and determines the plane shape, area size and size of each part of the room. In terms of structural design. The effects of constant load, live load, snow load, wind load and earthquake action were statistically analyzed. A truss of frame was used to calculate the internal forces under each load. Among them, the second moment distribution method (also known as layering method) is used for calculation under vertical load, and the d-value method is used for calculation under horizontal load. Calculate the income effect according to the durable design and seismic design conditions are combined, respectively, the durable design situation considering the control action of dead load and live load of control function, earthquake involving condition using the gravity load representative value 1.2 1.3 horizontal seismic action, choose the most unfavorable situation for beam, column, reinforcement calculation. The height is determined according to the punching failure, and the reinforcement is determined according to the bending failure of the foundation. For the reinforcement of other parts, PKPM was used for counting.
设计资料
1.1 工程概况
1 盐城林业局办公楼设计,主体五层,钢筋混凝土框架结构。梁板柱均为现浇,主楼建筑面积约5020㎡,建筑物平面一形。
2 建筑方案确定,柱距: 8m×8m;房间的开间一共为8.0m,房子的进深也为8.0m,房子的走廊宽为3.0m,房子的最底层层高为4.5m,房子的其它层层高4.2m,房子的室内外高差0.45m,其中标高相当于马路中心相对标高。