扬州宏森减震科技有限公司研发楼框架结构设计(方案1)毕业论文
2022-01-19 20:24:31
论文总字数:24728字
摘 要
本毕业设计题目为实际工程应用课题,位于扬州市,该工程为钢筋混凝土框架结构体系。房屋总高24.0米,地上六层。该楼楼层层高均为3.9m。总面积为8424mm²。为了提高整体抗震性能,本工程所有的梁板柱均为现浇。
本工程抗震设防烈度为7度,设计基本地震加速度值为0.15g,设计地震分组为第一组。工程场地无液化土层,属于Ⅰ类场地土。
关键词:框架结构 钢筋混凝土 建筑设计 结构设计
Abstract
The title of this graduation project is practical engineering application.It is located in Yangzhou City. The project is a reinforced concrete frame structure system. The total height of the house is 24.0 meters and the ground floor is six floors. The floor height of the building is 3.9 meters. The total area is 8424 square millimeters. In order to improve the overall seismic performance, all beams and columns of the project are cast-in-place.
The seismic fortification intensity of the project is 7 degrees, the basic seismic acceleration value is 0.15g, and the design earthquake group is the first group. The project site does not have liquefied soil layers and belongs to Class I site soil.
Key words: frame structure, reinforced concrete, building design,structural design
第一章 工程概况
图1-1 平面布置图
第二章 计算简图与荷载计算
一、确定计算简图
图2-1 计算简图
二、 梁、柱截面尺寸
1、 梁
横向框架梁:
AB、CD跨:∵h=(1/12~1/8)L=800mm~1200mm,取900mm
b=(1/3.5~1/2)h=258mm~450mm,取450mm
∴b×h=400mm×900mm
·BC跨:为计算简便,与AB跨取相同尺寸
∴b×h=250mm×400mm
次梁:∵h=(1/18~1/15)L=534mm~640mm,取600mm
b=(1/3.5~1/2)h=172mm~300mm,取250mm
∴b×h=250mm×600mm
纵向框架梁:∵h=(1/12~1/8)L=375mm~562.5mm,取500mm
b=(1/3.5~1/2)h=143mm~250mm,取250mm
∴b×h=250mm×500mm
2、 柱
边柱:
中柱:
3、 板厚
三、 材料强度等级
混凝土均采用C30级;受力钢筋采用HRB400钢筋,箍筋采用HPB300钢筋。
四、 荷载计算
图2-2 荷载计算简图
- 永久荷载作用下结构计算简图; (b)活载作用下结构计算简图
1、 屋面横梁竖向线荷载标准值
(1)永久荷载(图2-2a)
屋面永久荷载标准值
35㎜厚架空隔热板 0.035×25=0.875kN/㎡
防 水 层 0.4kN/㎡
20㎜厚1:2.5水泥砂浆找平层 0.02×20=0.4kN/㎡
100㎜钢筋混凝土板 0.10×25=2.5kN㎡
12厚纸筋石灰粉平顶 0.012×16=0.192kN/㎡
4.367kN/㎡
AB、BC、CD跨 0.4×0.9×25=9kN/m
梁侧粉刷 2×(0.9-0.1)×0.02×17=0.544kN/m
9.544kN/m
作用在顶层梁上的活荷载标准值为:
梁自重 g6AB1= g5BC1=g6CD1= 9.544kN/m
板传来的荷载 g6AB2=g6BC2 g6CD2= 4.367×2.25=9.826kN/m
(2)活荷载(图2-2b)
作用在顶层框架的活荷载标准值为
q5AB=q5BC= q5CD=0.5×2.25=1.125kN/m
2、 楼面横梁竖向线荷载标准值
(1)永久荷载(图2-2a)
25mm厚水泥砂浆面层 0.025×20=0.50kN/㎡
100厚钢筋混凝土现浇板 0.10×25=2.5kN/㎡
12厚板底粉刷 0.012×16=0.192kN/㎡
楼面永久荷载标准值 3.192kN/㎡
框架梁自重AB、BC、CD跨 9.544kN/m
作用在楼面层框架梁上的线恒荷载标准值
梁自重 gAB1=gBC1= gCD1=9.544kN/m板传来荷载 gAB2=gBC2=gCD2=3.192×2.25=7.182kN/m墙重 gAB3=gBC3=gCD3=(3.9-0.9)×2.36=7.08kN/m
(2)活荷载(图2-2b)
楼面活荷载 qAB=qCD=2.0×2.25=4.5kN/m
qBC=2.5×3.0=2.25kN/m
- 屋面框架节点集中荷载
计算简图及纵向框架梁偏心情况见图2-3。
图2-3 恒载顶层集中力
(1)永久荷载
边柱纵向框架梁自重 0.25×0.5×4.5×25=14.06kN 粉刷 2×(0.50-0.10)×0.02×4.5×17=1.04kN
0.6m高女儿墙 0.6×4.5×2.36=6.372kN
粉刷 0.6×2×0.02×4.5×17=1.836kN次梁自重 0.25×0.6×25×9.6/2=19.05kN粉刷 2×(0.6-0.1)×0.02×17×9.6/2=1.836kN次梁传来屋面重 4.367×4.5/2×9.6/2=47.164kN
顶层边节点集中荷载 G6A=G6D=90.104kN
中柱纵向框架梁自重 14.06kN粉刷 1.04kN
次梁自重 0.25×0.6×25×(9.6 4.8)/2=27kN
粉刷 2×(0.6-0.1)×0.02×17×(9.6 4.8)/2=2.448kN
次梁传来屋面重 4.367×4.5/2×(9.6 4.8)/2=19.05kN
顶层中结点集中荷载 G6B=G6C=115.293kN
(2)活荷载
Q6A=Q6D=0.5×4.5/2×9.6/2=5.4kN
Q6B=Q6C=0.5×4.5/2×(9.6 4.8)/2=8.1kN
4、楼面框架节点集中荷载标准值(图2-4)
图2-4 恒载中间层节点集中力
(1)永久荷载
边柱纵向框架梁自重 14.06kN
粉刷 1.04kN
钢窗自重 2.4×1.8×0.4=1.7281kN窗下墙体自重 (4.5-0.5)×(3.9-0.9-1.8)×2.36=11.328kN粉刷 2×4.0×1.2×0.02×17=3.264kN窗边墙体自重 1.8×(4.0-1.2)×2.36=6.797kN粉刷 2×1.8×1.6×0.02×17=1.958kN次梁自重 18kN粉刷 1.632kN 纵向框架梁传来楼面自重 3.192×4.5/2×9.6/2=34.474kN
94.281kN
中间层边节点集中荷载
柱传来集中荷载 GA=GD=94.281kN
框架柱自重 G‘A=G’D=0.5×0.5×3.9×25=24.375kN
中柱纵向框架梁自重 14.06kN
粉刷 1.04kN
内墙自重(忽略门窗自重) (4.5-0.5)×(3.9-0.9)×2.36=28.32kN
粉刷 2×4.0×3.0×0.02×17=8.16kN次梁自重 27kN粉刷 2.448kN
次梁传来楼面重 3.192×4.5/2×(9.6 4.8)/2=51.71kN
132.738kN
中间层中结点集中荷载
柱传来集中荷载 GB=GC=132.738kN
框架柱自重 G‘B=G‘C=24.375kN
(2)活荷载
请支付后下载全文,论文总字数:24728字