摘 要
本设计为昆山市某轻工厂职工公寓A楼,建筑主体为5层框架结构。设计内容包括建筑设计部分和结构设计部分。建筑设计部分包括建筑平面图、立面图、剖面图以及建筑说明图。结构设计时取一榀具有代表性的框架进行设计。结构计算内容有荷载计算、内力计算、内力组合、截面计算等几方面。在确定计算简图之后,按照有关设计规范和规定,采用弯矩分配法计算竖向荷载(恒载及活荷载)作用下的结构内力,再进行重力荷载代表值的计算,接着利用顶点位移法求出自振周期,按底部剪力法计算水平地震荷载作用大小,用D值法求出在水平地震作用和风荷载作用下的结构内力(弯矩、剪力、轴力)。由所得的内力进行内力组合,再找出最不利的一组或几组内力组合进行梁、柱的截面设计。截面设计时考虑“强柱弱梁、强剪弱弯”的原则进行内力调整。接着进行楼板、基础的设计,楼板的设计采用双向板设计。基础采用柱下独立基础,基础设计包括荷载计算、基础承载力计算、冲切计算、基础配筋计算等等。
关键词:框架结构;建筑设计;结构设计;抗震设计;基础设计
Abstract
The design of apartment building of factory , Kunshan. the main building is 5 story frame structure. The design content includes architectural design and structural design. Architectural design portion includes floor plans, elevations, sections and architectural description. Structure design is done with a representational framework design. Structure calculation contents include load calculation, internal force calculation, internal force combination, cross section calculation etc.. After determining the calculation diagram, according to relevant design standards and regulations, The internal force of the structure under vertical load (dead load and live load) is calculated by moment distribution method, the representative value of gravity load is calculated, the free vibration period is solved by vertex displacement method, the horizontal seismic load is calculated by equivalent base shear method, the structural internal forces (moment, shear, axial force) under the action of horizontal earthquake and wind load are solved by the D value method. The internal forces are combined, then the section of beam and column is designed according to the most disadvantaged group or several groups of internal force. The internal forces are adjusted according to the principle of "strong column and weak beam, strong shear and weak bending". Then the floor slab and foundation are designed. Slab is designed according to two-way slabs. The single foundation under column is used. The design of foundation include the calculation of load calculation, the calculation of bearing capacity of foundation, punching calculation and the calculation of foundation reinforcement etc..
Key Words: frame structure; architectural design; structural design; seismic design
目录
第一章 结构选型与布置 1
1.1结构选型与布置 1
1.2结构设计条件 1
1.2.1气象资料 1
1.2.2水文地质资料 1
1.2.3抗震设防烈度:七度。 1
1.2.4荷载资料 1
第二章 确定计算简图 3
2.1确定计算简图 3
2.2梁、柱截面尺寸 3
2.3材料强度等级 5
2.4荷载计算 5
2.4.1.屋面横梁竖向线荷载标准值 5
2.4.4.楼面框架节点集中荷载标准值 9
2.4.5.风荷载 10
2.4.6地震作用 11
第三章 框架内力计算 17
3.1计算方法 17
3.2恒载作用下的框架内力 17
3.2.1.弯矩分配系数 18
3.2.2杆件固端弯矩 20
3.2.3节点不平衡弯矩 21
3.2.4内力计算 21
3.2活载作用下的框架内力 27
3.2.1梁固端弯矩 27
3.2.2纵梁偏心引起的柱端附加弯矩 28
3.2.3本工程考虑如下四种最不利组合 28
3.2.4 内力计算 28
3.3风荷载作用下的框架内力 43
3.3.1水平风载作用下的框架层间剪力 43
3.3.2风荷载作用下的内力计算 44
3.4 地震作用横向框架的内力计算 47
3.4.1 0.5(雪 活)重力荷载作用下横向框架的内力计算 47
3.4.2地震作用下的矿建柱剪力及柱端弯矩内力计算 54
第四章框架内力组合 57
4.1内力调幅 57
第五章 框架梁柱截面设计 73
第六章楼梯结构计算设计 81
6.1基本理论 81
6.2毕业设计 83
6.2.1 梯段板计算 83
6.2.2休息平台板计算 84
6.2.3梯段梁TL1计算 85
第七章 现浇楼面板设计 86
7.1计算方法 86
2)求支座中点最大弯矩 87
7.2双向板设计 87
第八章 基础设计 91
8.1 荷载计算 91
8.2 确定基础底面积 92
8.2.1 A柱 92
8.2.2 B柱 93
8.2.3抗震验算 95
8.3 基础结构设计 96
8.3.1荷载设计值 96
8.3.3(B-C)柱基 98
参考文献 102
致 谢 103
请支付后下载全文,论文总字数:69599字