登录

  • 登录
  • 忘记密码?点击找回

注册

  • 获取手机验证码 60
  • 注册

找回密码

  • 获取手机验证码60
  • 找回
毕业论文网 > 毕业论文 > 土木建筑类 > 土木工程 > 正文

镇江句容某小区配套商业菜场(方案二)毕业论文

 2020-06-04 20:36:27  

摘 要

2.结构选型与布置 3

2.1 结构初选 3

2.2 结构布置 4

2.2.1 计算简图确定 4

3框架内力计算 5

3.1 竖向荷载内力计算 5

3.1.1 荷载取值 5

3.1.2 恒(活)荷载作用下横向框架计算 7

3.1.3恒(活)载作用下框架的弯矩计算 11

3.2 风荷载作用下内力计算 20

3.2.1 风荷载标准值 20

3.2.2 内力计算 20

3.3地震作用下横向框架内力计算 23

3.3.1. 重力荷载代表值计算 23

3.3.2.自震周期的计算 24

3.3.3地震位移演算 25

3.3.4水平地震作用下框架内力计算 27

4 框架内力组合 32

4.1 弯矩调幅 32

4.2内力组合 33

4.2.1 控制截面及最不利内力 35

5 框架梁柱截面设计 39

5.1 框架梁截面设计 40

5.1.1 正截面受弯承载力计算 41

5.2框架柱截面设计 43

5.2.1柱轴压比验算 47

5.2.2框架柱正截面承载力计算 48

5.2.3框架柱斜截面承载力计算 49

6 楼梯结构设计 49

6.1 梯段板(TB1,TB2)设计 47

6.2 平台板设计(PTB1) 48

6.3 平台梁设计(TL1) 48

7 现浇楼面板设计 49

7.1 内力计算 50

7.2配筋计算 51

8基础设计 55

8.1基础形式及荷载 55

8.2确定基础尺寸 57

8.3基础底板配筋 57

9 pkpm电算数据及应用. ..................................................................................58

10 结语和致谢..................................................................................................78

前言

本组毕业设计题目为《镇江句容某小区配套商业菜场(方案二)》 ,在毕业设计的 3 个月里,我复习了《结构力学》 、 《土力学》 、 《混凝土结构设计原理》 、《建筑抗震设计》 等知识,同时参考了《建筑结构荷载规范》 、《混凝土结构设计规范》 、 《砌体结构设计规范》 等规范。 通过所学的基本理论专业知识和基本技能进行建筑、 结构设计。

本设计主要进行了结构方案中横向 4 轴框架的抗震设计。在确定框架布局之后,先进行了层间荷载代表值的计算,接着利用顶点位移法求出自震周期,进而按底部剪力法计算水平地震荷载作用下大小, 进而求出在水平荷载作用下的结构内力(弯矩、剪力、轴力) 。接着计算竖向荷载(恒载及活荷载)作用下的结构内力, 最后找出最不利的一组或几组内力组合。选取最安全的结果计算配筋并绘图。此外还进行了结构方案中的室内楼梯的设计。完成了平台板,梯段板,平台梁等构件的内力和配筋计算及施工图绘制。

在指导老师的帮助下,经过资料查阅、设计计算、论文撰写,加深了对新规范、规程、手册等相关内容的理解。巩固了专业知识、提高了综合分析、解决问

题的能力。在进行内力组合的计算时,进一步了解了 Excel。在绘图时熟练掌握

了 AutoCAD,PKPM,以上所有这些从不同方面达到了毕业设计的目的与要求。

框架结构设计的计算工作量很大,在计算过程中通过手算和电算,对框架结

构进行受力分析,最终计算配筋及绘图。由于自己水平有限,难免有不妥和疏忽

之处,敬请各位老师批评指正。

南京市某小学综合楼设计(方案一)

摘要

本设计选取了⑥轴框架进行计算,计算书内容主要包括:结构选型、结构布置、确定计算简图、选择合理简单的计算方法进行各种荷载作用下的内力计算、荷载效应组合、截面配筋设计(计算、构造)、绘制施工图。其中地震作用采用底部剪力法确定,水平荷载作用下的内力采用 D 值法计算,竖向荷载作用下的内采用迭代法计算。 内力组合考虑无地震作用效应组合和有地震作用效应组合两种情况。由于此框架属于三级框架,所以没有进行节点抗震设计,但是在梁柱截面设计时采用了“强柱弱梁”的设计原则。楼梯采用板式楼梯。基础采用柱下独立基础。

在设计过程中采用电算对手算结果进行校核,及时发现设计中的错误以及与电算不同的部分,找出原因。

关键词:框架结构,内力组合,截面设计,柱下独立基础

Design of Primary School Complex in Jiangning District of Nanjing

窗体底端

(scheme one)

Abstract

This designchoose axis ⑥ frame calculate to load to go on,The content calculation include: Structural selection and arrangement、Determine the calculation diagram、choose a reasonable and simple calculation method for a variety of load under the force calculation、Load effect combination、Section reinforcement design (calculation, construction)、Draw construction drawings.Horizontal earthquake load is calculated by equivalent base shear method, internal force is calculated underlying horizontal loads by D value method ,internal force is calculated underlying vertical loads by iterative method.Earthquake is and not is considered in Combination of internal force. For this frame belonging to third class frame, not counting intersection of beams and columns, but this design obeys the design philosophy of “strong column and weak beam”. Staircase is plate-type. The foundation is independent foundation under column.

Hand computation is checked by computer in the course of counting, aiming to finding error and analyzing reason.

Key words :Frame structure,Combination of internal force, Section design, Independent foundation under column

2.结构选型与布置

2.1 结构初选

梁柱混凝土均采用C30级(fc=14.3N/mm2),梁、柱纵筋采用HRB400级(fy=fy=360 N/mm2),梁柱箍筋和板中钢筋均采用HPB300级(fy=fy=270 N/mm2)。

选取轴上一榀框架进行设计与计算。梁截面高度为h=(1/18~1/10)l,截面宽度为b=(1/4~1/2)h,则AB、CD跨:

h=(~1/10)l=(1/18~1/10)×8100=(450~810)mm,取h=700mm

b=(1/4~1/2)h=(1/4~1/2) ×700=(175~350)mm,取b=300mm

BC跨:取h=700mmb=300mm

同理,纵向框架梁取h=700mmb=300mm。次梁取h=600mmb=250mm。

框架柱截面按下式确定:

式中 A----柱全截面面积;

N----柱轴压力,N=(1.1~1.2)×(12~14)kN/m2×S,S为该柱承担的楼面荷载面积;

μ----柱轴压比限制,对于本设计三级框架取0.85。

中柱:

边柱:

三级抗震时柱截面不宜小于400,初选柱截面为600mm×600mm

2.2 结构布置

2.2.1 计算简图确定

框架柱轴线为截面形心线,框架梁的计算跨度取为框架柱截面形心之间的距离。底层柱高从基础顶面算至二层楼面标高处,中间层柱高从下一层楼地面标高至上一层楼地面标高。室外标高为-0.300m,考虑设备管线基础顶面至少应低于室外地面500mm,取为700mm,因此底层柱高为4.2 0.3 0.7=5.2m,其余各层柱高均为4.2m。框架计算简图如图2.1所示。

图1-1 横向框架计算简图

3框架内力计算

3.1 竖向荷载内力计算

3.1.1 荷载取值

1. 屋面及楼面恒载标准值:

屋面:

银色反光保护膜两度 0.2kN/m2

高分子卷材一层 0.3kN/m2

20mm厚1:3水泥砂浆找平

20厚1:6蛭石砂浆找坡

180厚挤压型聚苯乙烯板

100厚现浇钢筋混凝土楼板

20mm厚水泥砂浆顶棚

合计 4.5kN/m2

楼面:

8~10厚地砖铺实拍平,水泥砂浆擦缝

20厚1:4干硬性水泥砂浆

素水泥浆结合层一遍 0.7 kN/m2

100厚现浇钢筋混凝土楼板 2.5 kN/m2

20厚水泥砂浆顶棚 0.4 kN/m2

合计 3.60kN/m2

2. 构件自重

梁自重:

梁尺寸

梁自重

20mm厚水泥砂浆抹灰

合计 5.10 kN/m

梁尺寸

梁自重

20mm厚水泥砂浆抹灰

合计 3.63 kN/m

柱自重:

柱尺寸

梁自重

20mm厚水泥砂浆抹灰

合计 9.96 kN/m

3. 墙重

相关图片展示:

您需要先支付 80元 才能查看全部内容!立即支付

企业微信